Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Code | : | BV, H07V-U, NYA |
Standards | : | 227IEC01, BS 6004, VDE0281-3 |
Construction | : | 1- Solid Copper Conductor |
2- PVC insulation | ||
Application | : | Preferably for installation indoors, in cable ducts and in industrial plants or switching stations, |
under ground installation. | ||
Technical Data | : | Max. operating temperature 70 ºC |
Short circuit temperature 160 ºC |
Nominal Cross Section |
Wire Diameter |
Thickness of insulation |
Mean overall diameter |
Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
||
mm2 | No. ×mm | mm | min | max | Ù/km | kg/km | Pip A | Air A |
1.5 | 1.35 | 0.7 | 2.6 | 3.2 | 12.1 | 19 | 16 | 24 |
2.5 | 1.73 | 0.8 | 3.2 | 3.9 | 7.41 | 29 | 20 | 32 |
4 | 2.19 | 0.8 | 3.6 | 4.4 | 4.61 | 42 | 26 | 42 |
6 | 2.68 | 0.8 | 4.1 | 5.0 | 3.08 | 62 | 35 | 55 |
10 | 3.50 | 1.0 | 5.3 | 6.4 | 1.83 | 110 | 46 | 75 |
Code | : | H07V-R, NYA |
Standard | : | IEC 227, BS 6004,VDE 0281 |
Construction | : | 1- Stranded Copper Conductor |
2- PVC Insulation | ||
Application | : | Preferably for installation indoors. in cable ducts and in industrial plants or |
switching stations. under ground installation. | ||
Technical Data | : | Max. operating temperature 70ºC |
Short circuit temperature 160ºC |
Nominal Cross Section |
Number of wires and Dia. |
Thickness of insulation |
Mean overall diameter |
Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
||
mm2 | No. ×mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
1.5 | 7×0.51 | 0.7 | 2.7 | 3.3 | 12.1 | 22.0 | 16 | 25 |
2.5 | 7×0.66 | 0.8 | 3.3 | 4.0 | 7.41 | 36.0 | 20 | 34 |
4 | 7×0.83 | 0.8 | 3.8 | 4.6 | 4.61 | 52.0 | 26 | 45 |
6 | 7×1.02 | 0.8 | 4.3 | 5.2 | 3.08 | 74.0 | 35 | 57 |
10 | 7×1.32 | 1.0 | 5.6 | 6.7 | 1.83 | 110 | 46 | 75 |
16 | 7×1.68 | 1.0 | 6.4 | 7.8 | 1.15 | 170 | 62 | 100 |
25 | 7×2.20 | 1.2 | 8.1 | 9.7 | 0.727 | 265 | 82 | 130 |
35 | 7×2.55 | 1.2 | 9.0 | 10.9 | 0.524 | 360 | 100 | 160 |
50 | 7×3.00 | 1.4 | 10.6 | 12.8 | 0.387 | 501 | 120 | 200 |
Code | : | RV,H07V-K, NYAF |
Standard | : | IEC 227, VDE 0281, BS 6004 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC Insulation | ||
Application | : | For protected installation in equipment and lighting fitting. |
Also for in conduit, on and under plaster | ||
Technical Data | : | Max. operating temperature 70ºC |
Short circuit temperature 160ºC |
Nominal Cross Section |
Number of wires and Dia. |
Thickness of insulation |
Mean overall diameter |
Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
||
mm2 | No. ×mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
1.5 | 27×0.25 | 0.7 | 2.8 | 3.4 | 13.3 | 21.0 | 15 | 24 |
2.5 | 45×0.25 | 0.8 | 3.4 | 4.1 | 7.98 | 32.0 | 20 | 32 |
4 | 50×0.30 | 0.8 | 3.9 | 4.8 | 4.95 | 48.0 | 25 | 42 |
6 | 75×0.30 | 0.8 | 4.4 | 5.3 | 3.30 | 68.0 | 33 | 54 |
10 | 73×0.40 | 1.0 | 5.7 | 6.8 | 1.91 | 113 | 45 | 73 |
16 | 119×0.40 | 1.0 | 6.7 | 8.1 | 1.21 | 174 | 61 | 98 |
25 | 182×0.40 | 1.2 | 8.4 | 10.2 | 0.780 | 282 | 83 | 129 |
35 | 252×0.40 | 1.2 | 9.7 | 11.7 | 0.554 | 378 | 103 | 158 |
50 | 364×0.40 | 1.4 | 11.5 | 13.9 | 0.386 | 543 | 120 | 198 |
Code | : | H05VV-F, RVV |
Standard | : | IEC 227, VDE 0281, BS 6500 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation. 3- PVC Filling. 4- PVC Outer Sheath | ||
Application | : | For household appliances under medium mechanical stress-also in damp and wet areas |
Technical Data | : | Max. operating temperature 70ºC |
Short circuit temperature 160ºC |
Nominal Cross Section |
Number and Dia. |
Thickness of insulation |
Thickness of Sheath |
Mean overall diameter | Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
|
No | No. ×mm | mm | Mm | min | max | Ù/km | Kg/km | Air A |
2×0.75 | 22×0.20 | 0.6 | 0.8 | 5.7 | 7.2 | 26.0 | 57.1 | 8 |
2×1 | 30×0.20 | 0.6 | 0.8 | 5.9 | 7.5 | 19.5 | 64.0 | 12 |
2×1.5 | 27×0.25 | 0.7 | 0.8 | 6.8 | 8.6 | 13.3 | 91.0 | 18 |
2×2.5 | 45×0.25 | 0.8 | 1.0 | 8.4 | 10.6 | 7.98 | 135 | 26 |
2×4 | 50×0.30 | 0.8 | 1.1 | 9.7 | 12.1 | 4.95 | 189 | 32 |
2×6 | 75×0.30 | 0.8 | 1.1 | 11.8 | 13.1 | 3.30 | 274 | 42 |
2×10 | 73×0.40 | 0.9 | 1.2 | 14.6 | 15.8 | 1.91 | 422 | 70 |
3×0.75 | 22×0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 26.0 | 68.1 | 8 |
3×1 | 30×0.20 | 0.6 | 0.8 | 6.3 | 8.0 | 19.5 | 77.1 | 12 |
3×1.5 | 27×0.25 | 0.7 | 0.9 | 7.4 | 9.4 | 13.3 | 109 | 18 |
3×2.5 | 45×0.25 | 0.8 | 1.0 | 9.2 | 11.4 | 7.98 | 169 | 26 |
3×4 | 50×0.30 | 0.8 | 1.1 | 10.5 | 13.1 | 4.95 | 238 | 32 |
3×6 | 75×0.30 | 0.8 | 1.1 | 12.5 | 14.2 | 3.30 | 343 | 42 |
3×10 | 73×0.40 | 0.9 | 1.2 | 15.8 | 17.2 | 1.91 | 538 | 70 |
4×0.75 | 22×0.20 | 0.6 | 0.8 | 6.6 | 8.3 | 26.0 | 85.2 | 8 |
4×1 | 30×0.20 | 0.6 | 0.8 | 7.1 | 9.0 | 19.5 | 98.0 | 12 |
4×1.5 | 27×0.25 | 0.7 | 0.8 | 8.4 | 10.5 | 13.3 | 145 | 18 |
4×2.5 | 45×0.25 | 0.8 | 1.1 | 11.0 | 12.5 | 7.98 | 213 | 26 |
4×4 | 50×0.30 | 0.8 | 1.2 | 11.5 | 14.3 | 4.95 | 306 | 32 |
4×6 | 75×0.30 | 0.8 | 1.3 | 13.6 | 15.2 | 3.30 | 427 | 42 |
4×10 | 73×0.40 | 0.9 | 1.4 | 17.2 | 18.3 | 1.91 | 674 | 70 |
4×16 | 119×0.40 | 0.9 | 1.5 | 19.4 | 20.8 | 1.21 | 972 | 80 |
5×0.75 | 22×0.20 | 0.6 | 0.8 | 7.4 | 9.3 | 26.0 | 101 | 8 |
5×1 | 30×0.20 | 0.6 | 0.9 | 7.8 | 9.8 | 19.5 | 125 | 12 |
5×1.5 | 27×0.25 | 0.7 | 1.1 | 9.3 | 11.6 | 13.3 | 176 | 18 |
5×2.5 | 45×0.25 | 0.8 | 1.2 | 11.2 | 13.9 | 7.98 | 261 | 26 |
5×4 | 50×0.30 | 0.8 | 1.3 | 13.0 | 16.1 | 4.95 | 375 | 32 |
5×6 | 75×0.30 | 0.8 | 1.4 | 15.6 | 16.8 | 3.30 | 524 | 42 |
5×10 | 73×0.40 | 0.9 | 1.5 | 18.2 | 20.3 | 1.91 | 831 | 70 |
5×16 | 119×0.40 | 0.9 | 1.6 | 22.3 | 23.2 | 1.21 | 1170 | 80 |
Code | : | H05VVH2-F |
Standard | : | TS 9760, IEC 227, VDE 0281,BS 6500 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation | ||
3- PVC outer sheath | ||
Application | : | In dry. damp and wet locations as flexible connecting cables for light mechanical stresses. |
It is used for hand tools and house hold appliances with flat shape. | ||
Technical Data | : | Max. operating temperature 70ºC |
Short circuit temperature 160ºC |
Num. of Cores and Nominal Cross Section |
Number and Dia. |
Thickness of insulation |
Approx. OD |
Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
||
No×mm2 | No. ×mm | min | max | max.mm | Ù/km | Kg/km | Pip A | Air A |
2 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 4.00 × 6.40 | 26.0 | 37.0 | - | 13 |
2 × 1 | 30 × 0.20 | 0.6 | 0.8 | 4.10 × 6.60 | 19.5 | 61.1 | 12 | 16 |
2 × 1.5 | 27 × 0.25 | 0.7 | 0.8 | 4.60 × 7.60 | 13.3 | 85.0 | 16 | 20 |
2 × 2.5 | 45 × 0.25 | 0.8 | 1.0 | 5.70 × 9.40 | 7.98 | 128 | 21 | 27 |
2 × 4 | 50 × 0.30 | 0.8 | 1.1 | 6.40 × 10.6 | 4.95 | 185 | 27 | 36 |
3 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 4.00 × 8.80 | 26.0 | 65.0 | - | 13 |
3 × 1 | 30 × 0.20 | 0.6 | 0.8 | 4.10 × 9.10 | 19.5 | 77.0 | 12 | 16 |
3 × 1.5 | 27 × 0.25 | 0.7 | 0.9 | 4.70 × 10.50 | 13.3 | 104 | 16 | 20 |
3 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 5.90 × 13.30 | 7.98 | 159 | 21 | 27 |
3 × 4 | 50 × 0.30 | 0.8 | 1.2 | 6.60 × 15.60 | 4.95 | 228 | 27 | 36 |
Code | : | H05V2-K |
Standard | : | TS 9758, IEC 227, VDE 0281, BS 6004 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation | ||
Application | : | For protected installation in equipment and lighting fitting. |
Also for in conduit. on and under plaster. | ||
Technical Data | : | Max. operating temperature 90 ºC |
Short circuit temperature 160 ºC |
Nominal Cross Section |
Number and Dia. |
Thickness of insulation |
Mean overall diameter |
Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
||
mm2 | No. ×mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
0.5 | 15 × 0.20 | 0.6 | 2.1 | 2.5 | 39.0 | 10.0 | - | - |
0.75 | 22 × 0.20 | 0.6 | 2.2 | 2.7 | 26.0 | 12.0 | - | 16 |
1 | 30 × 0.20 | 0.6 | 2.4 | 2.8 | 19.5 | 15.0 | 12 | 20 |
Code | : | H07V2-K |
Standard | : | TS 9758, IEC 227, VDE 0281, BS 6004 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation | ||
Application | : | For protected installation in equipment and lighting fitting. |
Also for in conduit. on and under plaster. | ||
Technical Data | : | Max. operating temperature 90 ºC |
Short circuit temperature 160 ºC |
Nominal Cross Section |
Number and Dia. |
Thickness of insulation |
Mean overall diameter |
Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
||
mm2 | No. ×mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
1.5 | 27 × 0.25 | 0.7 | 2.8 | 3.4 | 13.3 | 21.0 | 15 | 24 |
2.5 | 45 × 0.25 | 0.8 | 3.4 | 4.1 | 7.98 | 32.0 | 20 | 32 |
4 | 50 × 0.30 | 0.8 | 3.9 | 4.8 | 4.95 | 48.0 | 25 | 42 |
6 | 75 × 0.30 | 0.8 | 4.4 | 5.3 | 3.30 | 68.0 | 33 | 54 |
10 | 73 × 0.40 | 1.0 | 5.7 | 6.8 | 1.91 | 113 | 45 | 73 |
16 | 119 × 0.40 | 1.0 | 6.7 | 8.1 | 1.21 | 174 | 61 | 98 |
25 | 182 × 0.40 | 1.2 | 8.4 | 10.2 | 0.780 | 282 | 83 | 129 |
35 | 252 × 0.40 | 1.2 | 9.7 | 11.7 | 0.554 | 378 | 103 | 158 |
50 | 364 × 0.40 | 1.4 | 11.5 | 13.9 | 0.386 | 543 | 132 | 198 |
Code | : | H05V2V2-F |
Standard | : | TS 9760, IEC 227, VDE 0281, BS 6500 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation | ||
3- PVC outer sheath | ||
Application | : | In dry. damp and wet locations as flexible connecting cables for light mechanical |
stresses. It is used for hand tools. heat tools and house hold appliances with flat shape. | ||
Technical Data | : | Max. operating temperature 90ºC |
Short circuit temperature 160 ºC |
Num. of Cores and Nominal Cross Section |
Number and Dia. |
Thickness of insulation |
Thickness of Sheath |
Mean overall diameter |
Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
|
No ×mm2 | mm | mm | min | max | Ù/km | Kg/km | Air A | |
2 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 5.7 | 7.2 | 26.0 | 57.0 | 8 |
2 × 1 | 30 × 0.20 | 0.6 | 0.8 | 5.9 | 7.5 | 19.5 | 64.1 | 12 |
2 × 1.5 | 27 × 0.25 | 0.7 | 0.8 | 6.8 | 8.6 | 13.3 | 91.0 | 18 |
2 × 2.5 | 45 × 0.25 | 0.8 | 1.0 | 8.4 | 10.6 | 7.98 | 135 | 26 |
2 × 4 | 50 × 0.30 | 0.8 | 1.1 | 9.7 | 12.1 | 4.95 | 189 | 32 |
2 × 6 | 75 × 0.30 | 0.8 | 1.1 | 11.8 | 13.1 | 3.30 | 274 | 42 |
2 × 10 | 73 × 0.40 | 0.9 | 1.2 | 14.6 | 15.8 | 1.91 | 422 | 70 |
3 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 26.0 | 68.1 | 8 |
3 × 1 | 30 × 0.20 | 0.6 | 0.8 | 6.3 | 8.0 | 19.5 | 77.0 | 12 |
3 × 1.5 | 27 × 0.25 | 0.7 | 0.9 | 7.4 | 9.4 | 13.3 | 109 | 18 |
3 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 9.2 | 11.4 | 7.98 | 169 | 26 |
3 × 4 | 50 × 0.30 | 0.8 | 1.2 | 10.5 | 13.1 | 4.95 | 238 | 32 |
3 × 6 | 75 × 0.30 | 0.8 | 1.1 | 12.5 | 14.2 | 3.30 | 343 | 42 |
3 × 10 | 73 × 0.40 | 0.9 | 1.2 | 15.8 | 17.2 | 1.91 | 538 | 70 |
4 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 6.6 | 8.3 | 26.0 | 85.0 | 8 |
4 × 1 | 30 × 0.20 | 0.6 | 0.8 | 7.1 | 9.0 | 19.5 | 98.0 | 12 |
4 × 1.5 | 27 × 0.25 | 0.7 | 0.8 | 8.4 | 10.5 | 13.3 | 145 | 18 |
4 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 11 | 12.5 | 7.98 | 213 | 26 |
4 × 4 | 50 × 0.30 | 0.8 | 1.2 | 11.5 | 14.3 | 4.95 | 306 | 32 |
4 × 6 | 75 × 0.30 | 0.8 | 1.3 | 13.6 | 15.2 | 3.30 | 427 | 42 |
4 × 10 | 73 × 0.40 | 0.9 | 1.4 | 17.2 | 18.3 | 1.91 | 674 | 70 |
4 × 16 | 119 × 0.40 | 0.9 | 1.5 | 19.4 | 20.8 | 1.21 | 972 | 80 |
5 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 7.4 | 9.3 | 26.0 | 101 | 8 |
5 × 1 | 30 × 0.20 | 0.6 | 0.9 | 7.8 | 9.8 | 19.5 | 125 | 12 |
5 × 1.5 | 27 × 0.25 | 0.7 | 1.0 | 9.3 | 11.6 | 13.3 | 176 | 18 |
5 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 11.2 | 13.9 | 7.98 | 261 | 26 |
5 × 4 | 50 × 0.30 | 0.8 | 1.3 | 13.0 | 16.1 | 4.95 | 375 | 32 |
5 × 6 | 75 × 0.30 | 0.8 | 1.4 | 15.6 | 16.8 | 3.30 | 524 | 42 |
5 × 10 | 73 × 0.40 | 0.9 | 1.5 | 18.2 | 20.3 | 1.91 | 831 | 70 |
Code | : | NVV |
Standard | : | TS 9759 HD 21,4 S2, VDE 0250-204, BS 6004 |
Construction | : | 1- Solid or Stranded Copper Conductor |
2- PVC insulation 3- PVC Filling 4- PVC outer sheath | ||
Application | : | Fixed wiring in dry and damp premises, in conduits. on or under plaster and on |
insulators over plaster, switching. | ||
Technical Data | : | Max. operating temperature 70ºC Short circuit temperature 160ºC |
Num. of Cores and Nominal Cross Section |
Number and Dia. |
Thickness of insulation |
Thickness of Sheath |
Mean overall diameter | Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
|
No ×mm2 | mm | mm | mm | min | max | Ù/km | Kg/km | Air A |
2 × 1.5 | 1.35 | 0.7 | 1.2 | 8.4 | 10.0 | 12.1 | 108 | 22 |
2 × 2.5 | 1.73 | 0.8 | 1.2 | 9.6 | 11.5 | 7.41 | 148 | 30 |
2 × 4 | 2.19 | 0.8 | 1.2 | 10.5 | 12.5 | 4.61 | 194 | 40 |
2 × 6 | 2.68 | 0.8 | 1.2 | 11.5 | 13.5 | 3.08 | 250 | 51 |
2 × 10 | 7 × 1.32 | 1.0 | 1.4 | 14.5 | 16.5 | 1.83 | 427 | 70 |
2 × 16 | 7 × 1.66 | 1.0 | 1.4 | 16.5 | 20.0 | 1.15 | 604 | 94 |
3 × 1.5 | 1.35 | 0.7 | 1.2 | 8.8 | 10.5 | 12.1 | 128 | 22 |
3 × 2.5 | 1.73 | 0.8 | 1.2 | 10.0 | 12.0 | 7.41 | 179 | 30 |
3 × 4 | 2.19 | 0.8 | 1.2 | 11.0 | 13.0 | 4.61 | 239 | 40 |
3 × 6 | 2.68 | 0.8 | 1.2 | 12.5 | 14.5 | 3.08 | 319 | 51 |
3 × 10 | 7 × 1.32 | 1.0 | 1.4 | 15.5 | 17.5 | 1.83 | 535 | 70 |
3 × 16 | 7 × 1.66 | 1.0 | 1.4 | 18.0 | 21.5 | 1.15 | 769 | 94 |
4 × 1.5 | 1.35 | 0.7 | 1.2 | 9.6 | 11.5 | 12.1 | 154 | 18.5 |
4 × 2.5 | 1.73 | 0.8 | 1.2 | 11.0 | 13.0 | 7.41 | 219 | 25 |
4 × 4 | 2.19 | 0.8 | 1.2 | 12.0 | 14.5 | 4.61 | 301 | 34 |
4 × 6 | 2.68 | 0.8 | 1.2 | 14.0 | 16.0 | 3.08 | 399 | 43 |
4 × 10 | 7 × 1.32 | 1.0 | 1.4 | 16.5 | 19.0 | 1.83 | 669 | 60 |
4 × 16 | 7 × 1.66 | 1.0 | 1.4 | 20.0 | 23.5 | 1.15 | 970 | 80 |
5 × 1.5 | 1.35 | 0.7 | 1.2 | 10.0 | 12.0 | 12.1 | 181 | 15.5 |
5 × 2.5 | 1.73 | 0.8 | 1.2 | 12.0 | 14.5 | 7.41 | 262 | 22 |
5 × 4 | 2.19 | 0.8 | 1.2 | 13.5 | 16.0 | 4.61 | 364 | 31 |
5 × 6 | 2.68 | 0.8 | 1.2 | 15.0 | 17.5 | 3.08 | 483 | 40 |
5 × 10 | 7 × 1.32 | 1.0 | 1.4 | 18.0 | 21.0 | 1.83 | 828 | 56.5 |
Code | : | Flat Cables |
Standard | : | TS 9760, IEC 227, VDE 0281, BS 6500 |
Construction | : | 1- Solid Copper Conductor |
2- PVC insulation | ||
3- PVC outer sheath | ||
Application | : | Preferably for installation indoors, in cable ducts and in industrial plants or switching |
stations, under ground installation, with additional protection where mechanical damage | ||
is unexpected. | ||
Technical Data | : | Max. operating temperature 70ºC |
Short circuit temperature 160ºC |
Num. of Cores and Nominal Cross Section |
Number and Dia. |
Thickness of insulation |
Thickness of Sheath |
Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
|
No. ×mm2 | No. ×mm | mm | mm | Ù/km | Kg/km | Pipe A | Air A |
2 × 1 | 1.1 | 0.6 | 0.8 | 18.1 | 50.0 | - | 19 |
2 × 1.5 | 1.35 | 0.7 | 0.8 | 12.1 | 66.0 | 32 | 20 |
2 × 2.5 | 1.73 | 0.8 | 1.0 | 7.41 | 104 | 42 | 20 |
2 × 4 | 2.19 | 0.8 | 1.1 | 4.61 | 143 | 54 | 20 |
3 × 1 | 1.1 | 0.6 | 0.8 | 18.1 | 73.0 | - | 20 |
3 × 1.5 | 1.35 | 0.7 | 0.9 | 12.1 | 101 | 26 | 20 |
3 × 2.5 | 1.73 | 0.8 | 1.1 | 7.41 | 158 | 34 | 20 |
3 × 4 | 2.19 | 0.8 | 1.2 | 4.61 | 216 | 44 | 20 |
Code | : | FLAT TWIN& THREE CORE CABLES |
Standard | : | BS6004 |
Construction | : | 1- Stranded Copper Conductor |
2- PVC insulation | ||
3- PVC outer sheath | ||
Application | : | These Cables are used in dry or damp locations for fixed installation. |
Suitable for installation in walls or embedded in plaster. | ||
Technical Data | : | Max. operating temperature 70ºC |
Num. of Cores and Nominal Cross Section |
Number and Dia. |
Thickness of insulation |
Thickness of Sheath |
Conductor DC resistance at 20ºC |
Approx. Total Weight |
Max. Current Carrying Capacity at 30ºC |
|
No ×mm2 | No. ×mm | mm | mm | Ù/km | Kg/km | Pipe A | Air A |
2 × 1.5 | 7 × 0.51 | 0.7 | 0.9 | 12.1 | 76..0 | 32 | 20 |
2 × 2.5 | 7 × 0.66 | 0.8 | 1.0 | 7.41 | 110 | 42 | 27 |
2 × 4 | 7 × 0.83 | 0.8 | 1.0 | 4.61 | 148 | 54 | 37 |
3 × 1.5 | 7 × 0.51 | 0.7 | 0.9 | 12.1 | 102 | 26 | 18 |
3 × 2.5 | 7 × 0.66 | 0.8 | 1.0 | 7.41 | 152 | 34 | 25 |
3 × 4 | 7 × 0.83 | 0.8 | 1.1 | 4.61 | 224 | 44 | 34 |