All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard

Product Details
Customization: Available
Type: Bare
Conductor Type: Stranded
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (9)
  • All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard
  • All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard
  • All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard
  • All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard
  • All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard
  • All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
AAAC
Application
Overhead
Conductor Material
6201-T81
Sheath Material
None
Insulation Material
None
Material Shape
Round Wire
Range of Application
Transmission and Distribution Line
Certification
ISO9001, CCC
Brand
QIFAN
Standard
IEC 61089, BS En 50182, ASTM B399, BS 3242
Strands No.
7, 19, 37, 61, 91, etc
Grease
None Grease or Greased Type Case 1, Case 2, Case 3
Transport Package
Wooden Drum, Wooden-Steel Drum
Specification
16-1000mm2, AWG or MCM, etc
Trademark
QIFAN
Origin
China
HS Code
7614900000
Production Capacity
200000kms Per Month

Product Description

All Aluminium Alloy Conductor,AAAC Cable with BS,ASTM,DIN,IEC,NFC Standard

Product Description

Concentric lay stranded Aluminium Alloy Conductors (AAAC) are made out of high strength Aluminium-Magnesium-Silicon Alloy. Midal manufactures and supply AAAC with different variants of electrical grade alloy type 6101 and 6201. one or more strands of hard drawn 1350 aluminium alloy.

These conductors are designed to get better strength to weight ratio and offer improved electrical properties, excellent sag-tension characteristics, and superior corrosion resistance when compared with ACSR. As compared to a conventional ACSR conductor, the lighter weight, comparable strength & current carrying capacity, lower electrical losses and superior corrosion resistance have given AAAC a wide acceptance in the distribution and medium & high voltage transmission lines..

Qifan can manufacture & supply AAAC on Non returnable wooden/steel reels or Returnable steel reels.

Product Parameters

AAAC stranded from 7strands to 91strands can be produced according to BS 3242, BS EN 50182,ASTM B399,DIN 48201,IEC 61089,NFC 34 125 standards.

AAAC  BS 3242 

Code name Nominal aluminium area Stranding and wire     diameter Sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
mm2 No./mm mm2 mm kg/km Ω/km kN
ALMOND 25 7/2.34 30.1 7.02 82 1.094 8.44
CEDAR 30 7/2.54 35.47 7.62 97 0.9281 9.94
FIR 40 7/2.95 47.84 8.85 131 0.688 13.4
HAZEL 50 7/3.30 59.87 9.9 164 0.5498 16.8
PINE 71.65 7/3.61 71.65 10.83 196 0.4591 21.14
OAK 100 7/4.65 118.9 13.95 325 0.2769 33.3
ASH 150 19/3.48 180.7 17.4 497 0.183 50.65
ELM 175 19/3.76 211 18.8 580 0.1568 59.1
UPAS 300 37/3.53 362.1 24.71 997 0.09155 101.5

 NFC 34 125

CODE NAME    AREA
mm2
NO. OF WIRES DIAMETER 
OF WIRES
mm
OVERALL 
DIAMETER
OF 
CONDUCTOR
mm
TENSILE 
STRENGTH 
OF WIRE
hbar
RATED 
STRENGTH 
OF 
CONDUCTOR
daN
MAXIMUM 
DC 
RESISTANCE AT 20ºC
km
LINEAR
WEIGHT
kg/km
ELASTICITY
MODULUS*
hbar
COEFFICIENT
OF LINEAR EXPANSION
*/oc
ASTER 22 21.99 7 2 6 32.4 710 1.5 60.2 6200 23.10-6
ASTER 34.4 34.36 7 2.5 7.5 32.4 1105 0.958 94.1 6200 23.10-6
ASTER 54.6 54.55 7 3.15 9.45 32.4 1755 0.603 149 6200 23.10-6
ASTER 75.5 75.54 19 2.25 11.25 32.4 2430 0.438 208 6000 23.10-6
ASTER 117 116.98 19 2.8 14 32.4 3765 0.283 322 6000 23.10-6
ASTER 148 148.01 19 3.15 15.75 32.4 4765 0.224 407 6000 23.10-6
ASTER 181.6 181.62 37 2.5 17.5 32.4 5845 0.183 500 5700 23.10-6
ASTER 228 227.83 37 2.8 19.6 32.4 7340 0.146 627 5700 23.10-6
ASTER 288 288.34 37 3.15 22.05 32.4 9280 0.115 794 5700 23.10-6
ASTER 366 366.22 37 3.55 24.85 32.4 11785 0.0905 1009 5700 23.10-6
ASTER 570 570.22 61 3.45 31.05 32.4 18360 0.0583 1574 5400 23.10-6
ASTER 851 850.66 91 3.45 37.95 32.4 27390 0.0391 2354 5250 23.10-6
ASTER 1144 1143.51 91 4 44 31.9 36260 0.0292 3164 5250 23.10-6
ASTER 1600 1595.93 127 4 52 31.9 50640 0.0206 4425 5050 23.10-6
 



AAAC BS EN 50182:2001

Code Name Stranding&wire diameter Approx Overall diameter Total area Weight Breaking Load DC Resistance at 20 Current Rating
mm mm mm 2 Kg/km KN Ohm/km A
Box 7/1.85 5.55 18.8 51.4 5.55 1.748 93
Acacia 7/2.08 6.24 23.9 64.9 7.02 1.3828 110
Almond 7/2.34 7.02 30.1 82.2 8.88 1.0926 128
Cedar 7/2.54 7.62 35.5 96.8 10.46 0.9273 132
Deodar 7/2.77 8.31 42.2 115.2 12.44 0.7797 148
Fir 7/2.95 8.85 47.8 130.6 14.11 0.6875 161
Hazel 7/3.30 9.9 59.9 163.4 17.66 0.5494 184
Pine 7/3.61 10.8 71.6 195.6 21.14 0.4591 204
Holly 7/3.91 11.7 84.1 229.5 24.79 0.3913 222
Willow 7/4.04 12.1 89.7 245 26.47 0.3665 233
Oak 7/4.65 13.95 118.9 324.5 35.07 0.2767 272
Mulbery 19/3.18 15.9 150.9 414.3 44.52 0.2192 319
Ash 19/3.48 17.4 180.7 496.1 53.31 0.183 354
Elm 19/3.76 18.8 211 579.2 62.24 0.1568 385
Poplar 37/2.87 20.1 239.4 659.4 70.61 0.1387 414
Sycamore 37/3.23 22.6 303.2 835.2 89.4 0.1095 487
Upas 37/3.53 24.7 362.1 997.5 106.82 0.0917 527
Yew 37/4.06 28.4 479 1319.6 141.31 0.0693 629
Totara 37/4.14 29.42 498.1 1372.1 146.93 0.0666 640
Rubus 61/3.50 31.5 586.9 1622 173.13 0.0567 716
Sorbus 61/3.71 33.4 659.4 1822.5 194.53 0.0505 760
Araucaria 61/4.14 37.3 821.1 2269.5 242.24 0.0406 842
Redwood 61/4.56 41 996.2 2753.2 293.88 0.0334 920
AAAC IEC1089-1997 Technical characteristics of A2 conductors
               
Code Number Area Number of wires Diameter of wire Diameter of conductor Linear mass Rated strenght D.C. resistance
mm2 mm mm Kg/km kN Ω/km
16 18.4 7 1.83 5.49 50.4 5.43 1.7896
25 28.8 7 2.29 6.87 78.7 8.49 1.1453
40 46.0 7 2.89 8.67 125.9 13.58 0.7158
63 72.5 7 3.36 10.80 198.3 21.39 0.4545
100 115.0 19 2.78 13.90 316.3 33.95 0.2877
125 144.0 19 3.10 15.50 395.4 42.44 0.2302
160 184.0 19 3.51 17.55 506.1 54.32 0.1798
200 230.0 19 3.93 19.65 632.7 67.91 0.1439
250 288.0 19 4.39 21.95 790.8 84.68 0.1151
315 363.0 37 3.53 24.71 998.9 106.95 0.0916
400 460.0 37 3.98 27.86 1268.4 135.81 0.0721
450 518.0 37 4.22 29.54 1426.9 152.79 0.0641
500 575.0 37 4.45 31.15 1585.5 169. 76 0.0577
560 645.0 61 3.67 33.03 1778.4 190.14 0.0516
630 725.0 61 3.89 35.01 2000.7 213.90 0.0458
710 817.0 61 4.13 37.17 2254.8 241.07 0.0407
800 921.0 61 4.38 39.42 2540.6 271.62 0.0361
900 1036.0 91 3.81 41.91 2861.1 305.58 0.0321
1000 1151.0 91 4.01 44.11 3179.0 339.53 0.0289
1120 1289.0 91 4.25 46.75 3560.5 380.27 0.0258
1250 1439.0 91 4.49 49.39 3973.7 424.41 0.0231


ASTM B399
 

Code word Conductor size Stranding Section area Diameter of conductor Linear mass Rated strength D.C. resistance at 20ºC
AWG (MCM) No./mm mm2 mm Kg/km kgf Ω/km
Akron   7/1.68 15.51 5.04 42.7 502 2.15980
  4 7/1.96 21.14 5.89 57.89 685 1.35570
Alton 48.69(4) 7/2.12 24.67 6.35 67.56 799 1.58600
  2 7/2.47 33.65 7.42 92.14 1091 0.99870
Ames 77.47(2) 7/2.67 39.26 8.02 107.50 1275 0.85470
  1/0 7/3.12 53.49 9.35 146.50 1733 0.62590
Azusa 123.3(1/0) 7/3. 37 62.46 10.11 171.00 2019 0.53650
  2/0 7/3.50 67.45 10.52 184.70 2090 0.49740
Anaheim 155.4(2/0) 7/3.78 78.75 11.35 215.16 2447 0.42640
  3/0 7/3.93 85.00 11.79 232.70 2641 0.39450
Amherst 195.7 (3/0) 7/4.25 99.20 12.75 271.50 3079 0.33730
  4/0 7/4.42 107.20 13.26 293.70 3334 0.31190
Alliance 246.9 (4/0) 7/4.77 125.10 14.30 342.60 3885 0.26780
  250.0 19/2.91 126.70 14.58 346.90 3977 0.26510
  300.0 19/3.19 152.10 15.89 418.60 4772 0.22060
Butte 312.8 19/3.26 158.50 16.31 434.00 4976 0.21120
  350.0 19/3.45 177.30 17.25 485.50 5333 0.18860
Canton 394.5 19/3.66 199.00 18.31 547.40 6016 0.16760
    19/3.69 202.70 18.44 555.10 6098 0.16490
  450.0 19/3.91 228.00 19.56 624.40 6862 0.14680
Cairo 456.4 19/3.98 235.80 19.89 645.70 7097 0.14310
  500.0 19/4.12 253.40 20.60 693.60 7617 0.13220
  550.0 37/3.10 278.70 21.67 762.90 8555 0.12000
Darien 559.5 19/4.36 283.50 21.79 776.30 8525 0.11810
  660.0 37/3.23 304.00 22.63 832.00 9330 0.11050
  650.0 37/3.37 329.40 23.57 909.80 10105 0.10150
Elgin 652.4 19/4.71 330.60 23.55 970.60 9942 0.10120
  700.0 37/3.49 354.50 24.46 910.60 10401 0.09464
Flint 740.8 37/3.59 375.40 25.15 1028.00 11013 0.08944
  750.0 37/3.62 380.20 25.32 1041.00 11216 0.08796
  800.0 37/3.73 405.40 26.14 1109.00 11930 0.08285
  900.0 37/3.96 456.30 27.74 1249.00 13460 0.07351
Greeley 927.2 37/4.02 469.80 28.14 1287.00 13868 0.07133
  1000.0 37/4.18 506.70 29.24 1388.00 14887 0.06597
  1077.4 61/3.38 483.40 30.42 1496.00 15907 0.06120
  1165.1 61/3.51 523.70 31.59 1617.00 17233 0.05675
  1250.0 61/3.63 633.30 32.67 1733.00 18354 0.05306
  1259.6 61/3.65 564.00 32.85 1748.00 18558 0.05248
  1348.8 61/3.78 604.20 34.02 1872.00 19884 0.04893
  1439.2 61/3.90 644.50 35.10 1997.00 21209 0.04597
  1500.0 61/3.98 760.00 35.82 2081.00 22127 0.04414
  1750.0 61/4.30 886.70 38.70 2429.00 25798 0.03781
Packaging & Shipping

All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC StandardAll Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC StandardAll Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard

Company Profile

All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier